We strive for excellence, services the customers, hopes to be the top cooperation team and dominator business for personnel, suppliers and prospects, realizes benefit share and continual promotion for Comparison Test Pumps, Calibrator, High Temperature Calibration Oil Bath, We have been pretty proud of your superior standing from our shoppers for our products' trustworthy quality.
2022 Good Quality Digital Pressure Manometer - PR9112 Intelligent Pressure Calibrator – Panran Detail:

Technical Parameters

Model

PR9112 Intelligent Pressure Calibrator

Pressure Measurement

Measurement Range

(-0.1~250)Mpa

Display accuracy

±0.05%F.S, ±0.02%F.S

Electric Current Measurement

Range

±30.0000mA

Sensitivity

0.1uA

Accuracy

±(0.01%R.D+0.003%F.S)

Voltage Measurement

Range

±30.0000V

Sensitivity

0.1mV

Accuracy

±(0.01%R.D +0.003%F.S)

Switching Value

A group of Power/outage measurement

Output function

Direct-current output

DC24V±0.5V

Operating Environmental

Working Temperature

(-20~50)℃

Relative Temperature

<95%

Storage Temperature

(-30~80)℃

Power Supply Configuration

Power supply mode

Lithium battery or power supply

Battery Operating Time

60 hours (24V with no load)

Charging time

About 4 hours

Other indicators

Size

115mm×45mm×180mm

Communication interface

specialized three-core aviation plug

Weight

0.8KG

Main Application:

1.Calibrate pressure (differential pressure) transmitter

2.Calibrate pressure switch

3.Verify the precision pressure gauge, General pressure gauge.

Product Feature:

1.Built-in manual operator function, The HART intelligent pressure transmitter can be calibrated.(optional)

2.Double-row liquid crystal display with backlight.

3.mmH2O、mmHg、psi、kPa、MPa、Pa、mbar、bar、kgf/c㎡, switch between nine pressure units.

4.With DC24V output function.

5.With current, voltage measurement.

6.Measuring with switching volume.

7.With communication interface.(optional)

8. Storage capacity: total 30 pcs file, (50 data records of each file)

9.Big screen crystal liquid display

Software Configuration:

PR9112S software of pressure verification system is the supporting software of our digital pressure calibrator series products in our company, Data collection records can be performed, Auto generated form, Automatic error calculation, Print certificate.

1.Routine Pressure Range Selection Table

No.

Pressure Range

Type

Class of accuracy

01

(-100~0) kPa

G

0.02/0.05

02

(0~60)Pa

G

0.2/0.05

03

(0~250)Pa

G

0.2/0.05

04

(0 ~ 1) kPa

G

0.05/0.1

05

(0 ~ 2) kPa

G

0.05/0.1

06

(0 ~ 2.5) kPa

G

0.05/0.1

07

(0 ~ 5) kPa

G

0.05/0.1

08

(0 ~ 10) kPa

G

0.05/0.1

09

(0 ~ 16) kPa

G

0.05/0.1

10

(0 ~ 25) kPa

G

0.05/0.1

11

(0 ~ 40) kPa

G

0.05/0.1

12

(0 ~ 60) kPa

G

0.05/0.1

13

(0 ~ 100) kPa

G

0.05/0.1

14

(0 ~ 160) kPa

G/L

0.02/0.05

15

(0 ~ 250) kPa

G/L

0.02/0.05

16

(0 ~ 400) kPa

G/L

0.02/0.05

17

(0 ~ 600) kPa

G/L

0.02/0.05

18

(0 ~ 1) MPa

G/L

0.02/0.05

19

(0 ~ 1.6) MPa

G/L

0.02/0.05

20

(0 ~ 2.5) MPa

G/L

0.02/0.05

21

(0 ~ 4) MPa

G/L

0.02/0.05

22

(0 ~ 6) MPa

G/L

0.02/0.05

23

(0 ~ 10) MPa

G/L

0.02/0.05

24

(0 ~ 16) MPa

G/L

0.02/0.05

25

(0 ~ 25) MPa

G/L

0.02/0.05

26

(0 ~ 40) MPa

G/L

0.02/0.05

27

(0 ~ 60) MPa

G/L

0.05/0.1

28

(0 ~ 100) MPa

G/L

0.05/0.1

29

(0 ~ 160) MPa

G/L

0.05/0.1

30

(0 ~ 250) MPa

G/L

0.05/0.1

Remarks: G=GasL=Liquid

2.Composite Pressure Range Selection Table:

No.

Pressure Range

Type

Class of accuracy

01

±60 Pa

G

0.2/0.5

02

±160 Pa

G

0.2/0.5

03

±250 Pa

G

0.2/0.5

04

±500 Pa

G

0.2/0.5

05

±1kPa

G

0.05/0.1

06

±2kPa

G

0.05/0.1

07

±2.5 kPa

G

0.05/0.1

08

±5kPa

G

0.05/0.1

09

±10kPa

G

0.05/0.1

10

±16kPa

G

0.05/0.1

11

±25kPa

G

0.05/0.1

12

±40kPa

G

0.05/0.1

13

±60kPa

G

0.05/0.1

14

±100kPa

G

0.02/0.05

15

(-100 ~160) kPa

G/L

0.02/0.05

16

(-100 ~250) kPa

G/L

0.02/0.05

17

(-100 ~400) kPa

G/L

0.02/0.05

18

(-100 ~600) kPa

G/L

0.02/0.05

19

(-0.1~1)Mpa

G/L

0.02/0.05

20

(-0.1~1.6)Mpa

G/L

0.02/0.05

21

(-0.1~2.5)Mpa

G/L

0.02/0.05

Remarks:

1.Partial range can do absolutely pressure

2.Automatic temperature compensation range:(-20~50℃)

3.Pressure transfer medium requires non-corrosive

<!–

Packing


Product detail pictures:

2022 Good Quality Digital Pressure Manometer - PR9112 Intelligent Pressure Calibrator – Panran detail pictures

2022 Good Quality Digital Pressure Manometer - PR9112 Intelligent Pressure Calibrator – Panran detail pictures


Related Product Guide:

Quality to start with, Honesty as base, Sincere company and mutual profit is our idea, as a way to build constantly and pursue the excellence for 2022 Good Quality Digital Pressure Manometer - PR9112 Intelligent Pressure Calibrator – Panran , The product will supply to all over the world, such as: Estonia, Sacramento, Japan, Due to good quality and reasonable prices, our products have been exported to more than 10 countries and regions. We are looking forward to cooperating with all customers from at home and abroad. Moreover, customer satisfaction is our eternal pursuit.
Adhering to the business principle of mutual benefits, we have a happy and successful transaction, we think we will be the best business partner.
5 Stars By Phoenix from San Francisco - 2018.09.23 18:44
After the signing of the contract, we received satisfactory goods in a short term, this is a commendable manufacturer.
5 Stars By Mario from Slovak Republic - 2018.12.05 13:53