With dependable high-quality method, fantastic standing and ideal purchaser assistance, the series of products produced by our firm are exported to many countries and regions for Black-Body Cavity Calibration Baths, High-Accuracy Dry-Well Calibrator, Portable Calibration Furnace, With our rules of business reputation, partner trust and mutual benefit, welcome all of you to work together , grow together.
Best quality Mercury Thermometer Calibration - PR1231/PR1232 Standard Platinum-10% Rhodium/Platium Thermocouple – Panran Detail:

PR1231/PR1232Standard Platinum-10% Rhodium/Platium Thermocouple

Part1 Overview

The first and second grade standard platinum-iridium 10-platinum thermocouples which have high accuracy good physical and chemical properties, good oxidation resistance at high temperatures, good stability and reproducibility of thermoelectromotive force. Therefore, it is used as a standard measuring instrument in (419.527~1084.62) °C , it is also used to temperature magnitude transmit and precision temperature measure in the temperature range.

Part2 Technical parameters

Parameter index

First grade platinum-iridium 10-platinum thermocouples

Second grade platinum-iridium 10-platinum thermocouples

Positive and negative

The positive is a platinum-rhodium alloy (platinum 90% rhodium 10%), the negative is pure platinum

electrode

Two electrodes diameter is 0.5-0.015mm length is no less than 1000mm

Requirements of the thermal electromotive force

Measure junction temperature is at Cu point(1084.62℃Al point(660.323℃)

Zn point(419.527℃) and reference junction temperature is 0℃

E(tCu)=10.575±0.015mV

E(tAl)=5.860+0.37 [E(tCu)-10.575]±0.005mV

E(tZn)=3.447+0.18 [E(tCu)-10.575]±0.005mV

Stability of Thermo-electromotive force

3μV

5μV

Annual change Thermo-electromotive force at Cu point(1084.62℃

≦5μV

≦10μV

Working Temperature Range

300~1100℃

Insulating sleeve

Double hole porcelain tube or corundum tube

Outer diameter(3~4)mm, hole diameter(0.8~1.0)mm, length(500~550)mm

Part3 Application Instructions

standard platinum-iridium 10-platinum thermocouples must be in accordance with the national delivery system table,National verification procedures must be implemented. First grade standard platinum-iridium 10-platinum thermocouples can be used to measure second grade,Ⅰ grade,Ⅱ grade platinum-iridium 10-platinum thermocouples and Ⅰ grade base metal thermocouples; Second grade platinum-iridium 10-platinum thermocouples can only used to measure Ⅱ grade base metal thermocouples

National verification code

National verification name

JJG75-1995

standard platinum-iridium 10-platinum thermocouples calibration specification

JJG141-2013

Working precious metal thermocouples calibration specification

JJF1637-2017

base metal thermocouple calibration specification

Part4 Maintenance and preservation

1. The standard thermocouple calibration period is 1 year, and every year the standard thermocouple must be calibrated by metrology department.

2. The necessary supervisory calibration should be performed according to the usage.

3. The work environment of the standard thermocouple should be clean to avoid contamination of the standard thermocouple.

4. The standard thermocouple should be placed in a non-polluting condition and protected from mechanical stress.

Part5 Precautions when use

1. The insulation tube cannot be used at high temperature roasting. The original insulation tube is used after strict cleaning and high temperature roasting.

2. The insulation tube ignores positive and negative, which will cause the platinum pole to be contaminated and the thermoelectric potential value to decrease.

3. Randomly the standard thermocouple insulation tube with cheap wire will contaminate the standard thermocouple, and the protective metal tube must be used for the verification of the base metal thermocouple.

4. The standard thermocouple cannot be suddenly placed in the temperature-regulating furnace, nor be taken out from the temperature-regulating furnace. The sudden-heat and cold will affect the thermoelectric performance

5.Under normal circumstances, the verification furnace for the precious metal thermocouple and the base metal thermocouple should be strictly distinguished; if it is impossible, the clean ceramic tube or corundum tube(diameter about 15mm) should be inserted to the furnace tube for protecting precious metal Thermocouples and standard thermocouples from base metal thermocouple pollution.


Product detail pictures:

Best quality	Mercury Thermometer Calibration	- PR1231/PR1232 Standard Platinum-10% Rhodium/Platium Thermocouple – Panran detail pictures

Best quality	Mercury Thermometer Calibration	- PR1231/PR1232 Standard Platinum-10% Rhodium/Platium Thermocouple – Panran detail pictures

Best quality	Mercury Thermometer Calibration	- PR1231/PR1232 Standard Platinum-10% Rhodium/Platium Thermocouple – Panran detail pictures

Best quality	Mercury Thermometer Calibration	- PR1231/PR1232 Standard Platinum-10% Rhodium/Platium Thermocouple – Panran detail pictures


Related Product Guide:

Our purpose is to fulfill our clients by offering golden company, great price and premium quality for Best quality Mercury Thermometer Calibration - PR1231/PR1232 Standard Platinum-10% Rhodium/Platium Thermocouple – Panran , The product will supply to all over the world, such as: Latvia, Lithuania, Bandung, Now, we professionally supplies customers with our main merchandise And our business is not only the buy and sell, but also focus on more. We target to be your loyal supplier and long-term cooperator in China. Now, We hope to be the friends with you.
The company comply with the contract strict, a very reputable manufacturers, worthy a long-term cooperation.
5 Stars By Norma from Swaziland - 2017.11.20 15:58
With a positive attitude of regard the market, regard the custom, regard the science, the company works actively to do research and development. Hope we have a future business relationships and achieving mutual success.
5 Stars By Danny from Paris - 2017.03.28 12:22