Technical Parameters
|
Model |
PR9112 Intelligent Pressure Calibrator |
|
|
Pressure Measurement |
Measurement Range |
(-0.1~250)Mpa |
|
Display accuracy |
±0.05%F.S, ±0.02%F.S |
|
|
Electric Current Measurement |
Range |
±30.0000mA |
|
Sensitivity |
0.1uA |
|
|
Accuracy |
±(0.01%R.D+0.003%F.S) |
|
|
Voltage Measurement |
Range |
±30.0000V |
|
Sensitivity |
0.1mV |
|
|
Accuracy |
±(0.01%R.D +0.003%F.S) |
|
|
Switching Value |
A group of Power/outage measurement |
|
|
Output function |
Direct-current output |
DC24V±0.5V |
|
Operating Environmental |
Working Temperature |
(-20~50)℃ |
|
Relative Temperature |
<95% |
|
|
Storage Temperature |
(-30~80)℃ |
|
|
Power Supply Configuration |
Power supply mode |
Lithium battery or power supply |
|
Battery Operating Time |
60 hours (24V with no load) |
|
|
Charging time |
About 4 hours |
|
|
Other indicators |
Size |
115mm×45mm×180mm |
|
Communication interface |
specialized three-core aviation plug |
|
|
Weight |
0.8KG |
|
Main Application:
1.Calibrate pressure (differential pressure) transmitter
2.Calibrate pressure switch
3.Verify the precision pressure gauge, General pressure gauge.
Product Feature:
1.Built-in manual operator function, The HART intelligent pressure transmitter can be calibrated.(optional)
2.Double-row liquid crystal display with backlight.
3.mmH2O、mmHg、psi、kPa、MPa、Pa、mbar、bar、kgf/c㎡, switch between nine pressure units.
4.With DC24V output function.
5.With current, voltage measurement.
6.Measuring with switching volume.
7.With communication interface.(optional)
8. Storage capacity: total 30 pcs file, (50 data records of each file)
9.Big screen crystal liquid display
Software Configuration:
PR9112S software of pressure verification system is the supporting software of our digital pressure calibrator series products in our company, Data collection records can be performed, Auto generated form, Automatic error calculation, Print certificate.
1.Routine Pressure Range Selection Table
|
No. |
Pressure Range |
Type |
Class of accuracy |
|
01 |
(-100~0) kPa |
G |
0.02/0.05 |
|
02 |
(0~60)Pa |
G |
0.2/0.05 |
|
03 |
(0~250)Pa |
G |
0.2/0.05 |
|
04 |
(0 ~ 1) kPa |
G |
0.05/0.1 |
|
05 |
(0 ~ 2) kPa |
G |
0.05/0.1 |
|
06 |
(0 ~ 2.5) kPa |
G |
0.05/0.1 |
|
07 |
(0 ~ 5) kPa |
G |
0.05/0.1 |
|
08 |
(0 ~ 10) kPa |
G |
0.05/0.1 |
|
09 |
(0 ~ 16) kPa |
G |
0.05/0.1 |
|
10 |
(0 ~ 25) kPa |
G |
0.05/0.1 |
|
11 |
(0 ~ 40) kPa |
G |
0.05/0.1 |
|
12 |
(0 ~ 60) kPa |
G |
0.05/0.1 |
|
13 |
(0 ~ 100) kPa |
G |
0.05/0.1 |
|
14 |
(0 ~ 160) kPa |
G/L |
0.02/0.05 |
|
15 |
(0 ~ 250) kPa |
G/L |
0.02/0.05 |
|
16 |
(0 ~ 400) kPa |
G/L |
0.02/0.05 |
|
17 |
(0 ~ 600) kPa |
G/L |
0.02/0.05 |
|
18 |
(0 ~ 1) MPa |
G/L |
0.02/0.05 |
|
19 |
(0 ~ 1.6) MPa |
G/L |
0.02/0.05 |
|
20 |
(0 ~ 2.5) MPa |
G/L |
0.02/0.05 |
|
21 |
(0 ~ 4) MPa |
G/L |
0.02/0.05 |
|
22 |
(0 ~ 6) MPa |
G/L |
0.02/0.05 |
|
23 |
(0 ~ 10) MPa |
G/L |
0.02/0.05 |
|
24 |
(0 ~ 16) MPa |
G/L |
0.02/0.05 |
|
25 |
(0 ~ 25) MPa |
G/L |
0.02/0.05 |
|
26 |
(0 ~ 40) MPa |
G/L |
0.02/0.05 |
|
27 |
(0 ~ 60) MPa |
G/L |
0.05/0.1 |
|
28 |
(0 ~ 100) MPa |
G/L |
0.05/0.1 |
|
29 |
(0 ~ 160) MPa |
G/L |
0.05/0.1 |
|
30 |
(0 ~ 250) MPa |
G/L |
0.05/0.1 |
Remarks: G=GasL=Liquid
2.Composite Pressure Range Selection Table:
|
No. |
Pressure Range |
Type |
Class of accuracy |
|
01 |
±60 Pa |
G |
0.2/0.5 |
|
02 |
±160 Pa |
G |
0.2/0.5 |
|
03 |
±250 Pa |
G |
0.2/0.5 |
|
04 |
±500 Pa |
G |
0.2/0.5 |
|
05 |
±1kPa |
G |
0.05/0.1 |
|
06 |
±2kPa |
G |
0.05/0.1 |
|
07 |
±2.5 kPa |
G |
0.05/0.1 |
|
08 |
±5kPa |
G |
0.05/0.1 |
|
09 |
±10kPa |
G |
0.05/0.1 |
|
10 |
±16kPa |
G |
0.05/0.1 |
|
11 |
±25kPa |
G |
0.05/0.1 |
|
12 |
±40kPa |
G |
0.05/0.1 |
|
13 |
±60kPa |
G |
0.05/0.1 |
|
14 |
±100kPa |
G |
0.02/0.05 |
|
15 |
(-100 ~160) kPa |
G/L |
0.02/0.05 |
|
16 |
(-100 ~250) kPa |
G/L |
0.02/0.05 |
|
17 |
(-100 ~400) kPa |
G/L |
0.02/0.05 |
|
18 |
(-100 ~600) kPa |
G/L |
0.02/0.05 |
|
19 |
(-0.1~1)Mpa |
G/L |
0.02/0.05 |
|
20 |
(-0.1~1.6)Mpa |
G/L |
0.02/0.05 |
|
21 |
(-0.1~2.5)Mpa |
G/L |
0.02/0.05 |
Remarks:
1.Partial range can do absolutely pressure
2.Automatic temperature compensation range:(-20~50℃)
3.Pressure transfer medium requires non-corrosive
<!–
Packing
Product detail pictures:
Related Product Guide:
We believe in: Innovation is our soul and spirit. Quality is our life. Customer need is our God for China wholesale Pressure And Temperature Calibrator - PR9112 Intelligent Pressure Calibrator – Panran , The product will supply to all over the world, such as: Romania, Swaziland, Kuwait, Our products are exported worldwide. Our customers are always satisfied with our reliable quality, customer-oriented services and competitive prices. Our mission is to continue to earn your loyalty by dedicating our efforts to the constant improvement of our products and services in order to ensure the satisfaction of our end-users, customers, employees, suppliers and the worldwide communities in which we cooperate.
It can be said that this is a best producer we encountered in China in this industry, we feel lucky to work with so excellent manufacturer.