Factory wholesale Thermometer Calibration Temperature - PR1231/PR1232 Standard Platinum-10% Rhodium/Platium Thermocouple – Panran

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Quality 1st, Honesty as base, Sincere company and mutual profit is our idea, in an effort to create consistently and pursue the excellence for Low Pressure Pneumatic Test Pump, Temperature And Humidity Standard Chamber For Hygrometer Calibration, Handheld Pneumatic Pressure Test Pump, We appreciate your enquiry and it's our honor to work with every friend worldwide.
Factory wholesale Thermometer Calibration Temperature - PR1231/PR1232 Standard Platinum-10% Rhodium/Platium Thermocouple – Panran Detail:

PR1231/PR1232Standard Platinum-10% Rhodium/Platium Thermocouple

Part1 Overview

The first and second grade standard platinum-iridium 10-platinum thermocouples which have high accuracy good physical and chemical properties, good oxidation resistance at high temperatures, good stability and reproducibility of thermoelectromotive force. Therefore, it is used as a standard measuring instrument in (419.527~1084.62) °C , it is also used to temperature magnitude transmit and precision temperature measure in the temperature range.

Part2 Technical parameters

Parameter index

First grade platinum-iridium 10-platinum thermocouples

Second grade platinum-iridium 10-platinum thermocouples

Positive and negative

The positive is a platinum-rhodium alloy (platinum 90% rhodium 10%), the negative is pure platinum

electrode

Two electrodes diameter is 0.5-0.015mm length is no less than 1000mm

Requirements of the thermal electromotive force

Measure junction temperature is at Cu point(1084.62℃Al point(660.323℃)

Zn point(419.527℃) and reference junction temperature is 0℃

E(tCu)=10.575±0.015mV

E(tAl)=5.860+0.37 [E(tCu)-10.575]±0.005mV

E(tZn)=3.447+0.18 [E(tCu)-10.575]±0.005mV

Stability of Thermo-electromotive force

3μV

5μV

Annual change Thermo-electromotive force at Cu point(1084.62℃

≦5μV

≦10μV

Working Temperature Range

300~1100℃

Insulating sleeve

Double hole porcelain tube or corundum tube

Outer diameter(3~4)mm, hole diameter(0.8~1.0)mm, length(500~550)mm

Part3 Application Instructions

standard platinum-iridium 10-platinum thermocouples must be in accordance with the national delivery system table,National verification procedures must be implemented. First grade standard platinum-iridium 10-platinum thermocouples can be used to measure second grade,Ⅰ grade,Ⅱ grade platinum-iridium 10-platinum thermocouples and Ⅰ grade base metal thermocouples; Second grade platinum-iridium 10-platinum thermocouples can only used to measure Ⅱ grade base metal thermocouples

National verification code

National verification name

JJG75-1995

standard platinum-iridium 10-platinum thermocouples calibration specification

JJG141-2013

Working precious metal thermocouples calibration specification

JJF1637-2017

base metal thermocouple calibration specification

Part4 Maintenance and preservation

1. The standard thermocouple calibration period is 1 year, and every year the standard thermocouple must be calibrated by metrology department.

2. The necessary supervisory calibration should be performed according to the usage.

3. The work environment of the standard thermocouple should be clean to avoid contamination of the standard thermocouple.

4. The standard thermocouple should be placed in a non-polluting condition and protected from mechanical stress.

Part5 Precautions when use

1. The insulation tube cannot be used at high temperature roasting. The original insulation tube is used after strict cleaning and high temperature roasting.

2. The insulation tube ignores positive and negative, which will cause the platinum pole to be contaminated and the thermoelectric potential value to decrease.

3. Randomly the standard thermocouple insulation tube with cheap wire will contaminate the standard thermocouple, and the protective metal tube must be used for the verification of the base metal thermocouple.

4. The standard thermocouple cannot be suddenly placed in the temperature-regulating furnace, nor be taken out from the temperature-regulating furnace. The sudden-heat and cold will affect the thermoelectric performance

5.Under normal circumstances, the verification furnace for the precious metal thermocouple and the base metal thermocouple should be strictly distinguished; if it is impossible, the clean ceramic tube or corundum tube(diameter about 15mm) should be inserted to the furnace tube for protecting precious metal Thermocouples and standard thermocouples from base metal thermocouple pollution.


Product detail pictures:

Factory wholesale	Thermometer Calibration Temperature	- PR1231/PR1232 Standard Platinum-10% Rhodium/Platium Thermocouple – Panran detail pictures

Factory wholesale	Thermometer Calibration Temperature	- PR1231/PR1232 Standard Platinum-10% Rhodium/Platium Thermocouple – Panran detail pictures

Factory wholesale	Thermometer Calibration Temperature	- PR1231/PR1232 Standard Platinum-10% Rhodium/Platium Thermocouple – Panran detail pictures

Factory wholesale	Thermometer Calibration Temperature	- PR1231/PR1232 Standard Platinum-10% Rhodium/Platium Thermocouple – Panran detail pictures


Related Product Guide:

We know that we only thrive if we will guarantee our combined cost competiveness and high-quality advantageous at the same time for Factory wholesale Thermometer Calibration Temperature - PR1231/PR1232 Standard Platinum-10% Rhodium/Platium Thermocouple – Panran , The product will supply to all over the world, such as: Luxembourg, South Korea, Luxemburg, The company attaches great importance to product quality and service quality, based on the business philosophy good with people, genuine to whole world, your satisfaction is our pursuit. we design products, According to customer's sample and requirements, to meet the needs of the market and offer different customers with personalized service. Our company warmly welcomes friends at home and abroad to visit, to discuss cooperation and seek common development!
Goods just received, we are very satisfied, a very good supplier, hope to make persistent efforts to do better.
5 Stars By Alexandra from Burundi - 2018.02.12 14:52
This is a reputable company, they have a high level of business management, good quality product and service, every cooperation is assured and delighted!
5 Stars By Bella from French - 2018.12.05 13:53