Professional China Digital Pressure Gauge Calibrator – PR9112 Intelligent Pressure Calibrator – Panran
Professional China Digital Pressure Gauge Calibrator – PR9112 Intelligent Pressure Calibrator – Panran Detail:
Technical Parameters
|
Model |
PR9112 Intelligent Pressure Calibrator |
|
|
Pressure Measurement |
Measurement Range |
(-0.1~250)Mpa |
|
Display accuracy |
±0.05%F.S, ±0.02%F.S |
|
|
Electric Current Measurement |
Range |
±30.0000mA |
|
Sensitivity |
0.1uA |
|
|
Accuracy |
±(0.01%R.D+0.003%F.S) |
|
|
Voltage Measurement |
Range |
±30.0000V |
|
Sensitivity |
0.1mV |
|
|
Accuracy |
±(0.01%R.D +0.003%F.S) |
|
|
Switching Value |
A group of Power/outage measurement |
|
|
Output function |
Direct-current output |
DC24V±0.5V |
|
Operating Environmental |
Working Temperature |
(-20~50)℃ |
|
Relative Temperature |
<95% |
|
|
Storage Temperature |
(-30~80)℃ |
|
|
Power Supply Configuration |
Power supply mode |
Lithium battery or power supply |
|
Battery Operating Time |
60 hours (24V with no load) |
|
|
Charging time |
About 4 hours |
|
|
Other indicators |
Size |
115mm×45mm×180mm |
|
Communication interface |
specialized three-core aviation plug |
|
|
Weight |
0.8KG |
|
Main Application:
1.Calibrate pressure (differential pressure) transmitter
2.Calibrate pressure switch
3.Verify the precision pressure gauge, General pressure gauge.
Product Feature:
1.Built-in manual operator function, The HART intelligent pressure transmitter can be calibrated.(optional)
2.Double-row liquid crystal display with backlight.
3.mmH2O、mmHg、psi、kPa、MPa、Pa、mbar、bar、kgf/c㎡, switch between nine pressure units.
4.With DC24V output function.
5.With current, voltage measurement.
6.Measuring with switching volume.
7.With communication interface.(optional)
8. Storage capacity: total 30 pcs file, (50 data records of each file)
9.Big screen crystal liquid display
Software Configuration:
PR9112S software of pressure verification system is the supporting software of our digital pressure calibrator series products in our company, Data collection records can be performed, Auto generated form, Automatic error calculation, Print certificate.
1.Routine Pressure Range Selection Table
|
No. |
Pressure Range |
Type |
Class of accuracy |
|
01 |
(-100~0) kPa |
G |
0.02/0.05 |
|
02 |
(0~60)Pa |
G |
0.2/0.05 |
|
03 |
(0~250)Pa |
G |
0.2/0.05 |
|
04 |
(0 ~ 1) kPa |
G |
0.05/0.1 |
|
05 |
(0 ~ 2) kPa |
G |
0.05/0.1 |
|
06 |
(0 ~ 2.5) kPa |
G |
0.05/0.1 |
|
07 |
(0 ~ 5) kPa |
G |
0.05/0.1 |
|
08 |
(0 ~ 10) kPa |
G |
0.05/0.1 |
|
09 |
(0 ~ 16) kPa |
G |
0.05/0.1 |
|
10 |
(0 ~ 25) kPa |
G |
0.05/0.1 |
|
11 |
(0 ~ 40) kPa |
G |
0.05/0.1 |
|
12 |
(0 ~ 60) kPa |
G |
0.05/0.1 |
|
13 |
(0 ~ 100) kPa |
G |
0.05/0.1 |
|
14 |
(0 ~ 160) kPa |
G/L |
0.02/0.05 |
|
15 |
(0 ~ 250) kPa |
G/L |
0.02/0.05 |
|
16 |
(0 ~ 400) kPa |
G/L |
0.02/0.05 |
|
17 |
(0 ~ 600) kPa |
G/L |
0.02/0.05 |
|
18 |
(0 ~ 1) MPa |
G/L |
0.02/0.05 |
|
19 |
(0 ~ 1.6) MPa |
G/L |
0.02/0.05 |
|
20 |
(0 ~ 2.5) MPa |
G/L |
0.02/0.05 |
|
21 |
(0 ~ 4) MPa |
G/L |
0.02/0.05 |
|
22 |
(0 ~ 6) MPa |
G/L |
0.02/0.05 |
|
23 |
(0 ~ 10) MPa |
G/L |
0.02/0.05 |
|
24 |
(0 ~ 16) MPa |
G/L |
0.02/0.05 |
|
25 |
(0 ~ 25) MPa |
G/L |
0.02/0.05 |
|
26 |
(0 ~ 40) MPa |
G/L |
0.02/0.05 |
|
27 |
(0 ~ 60) MPa |
G/L |
0.05/0.1 |
|
28 |
(0 ~ 100) MPa |
G/L |
0.05/0.1 |
|
29 |
(0 ~ 160) MPa |
G/L |
0.05/0.1 |
|
30 |
(0 ~ 250) MPa |
G/L |
0.05/0.1 |
Remarks: G=GasL=Liquid
2.Composite Pressure Range Selection Table:
|
No. |
Pressure Range |
Type |
Class of accuracy |
|
01 |
±60 Pa |
G |
0.2/0.5 |
|
02 |
±160 Pa |
G |
0.2/0.5 |
|
03 |
±250 Pa |
G |
0.2/0.5 |
|
04 |
±500 Pa |
G |
0.2/0.5 |
|
05 |
±1kPa |
G |
0.05/0.1 |
|
06 |
±2kPa |
G |
0.05/0.1 |
|
07 |
±2.5 kPa |
G |
0.05/0.1 |
|
08 |
±5kPa |
G |
0.05/0.1 |
|
09 |
±10kPa |
G |
0.05/0.1 |
|
10 |
±16kPa |
G |
0.05/0.1 |
|
11 |
±25kPa |
G |
0.05/0.1 |
|
12 |
±40kPa |
G |
0.05/0.1 |
|
13 |
±60kPa |
G |
0.05/0.1 |
|
14 |
±100kPa |
G |
0.02/0.05 |
|
15 |
(-100 ~160) kPa |
G/L |
0.02/0.05 |
|
16 |
(-100 ~250) kPa |
G/L |
0.02/0.05 |
|
17 |
(-100 ~400) kPa |
G/L |
0.02/0.05 |
|
18 |
(-100 ~600) kPa |
G/L |
0.02/0.05 |
|
19 |
(-0.1~1)Mpa |
G/L |
0.02/0.05 |
|
20 |
(-0.1~1.6)Mpa |
G/L |
0.02/0.05 |
|
21 |
(-0.1~2.5)Mpa |
G/L |
0.02/0.05 |
Remarks:
1.Partial range can do absolutely pressure
2.Automatic temperature compensation range:(-20~50℃)
3.Pressure transfer medium requires non-corrosive
<!–
Packing
Product detail pictures:
Related Product Guide:
Our mission should be to turn out to be an innovative supplier of high-tech digital and communication devices by furnishing benefit added design and style, world-class manufacturing, and repair capabilities for Professional China Digital Pressure Gauge Calibrator – PR9112 Intelligent Pressure Calibrator – Panran , The product will supply to all over the world, such as: Hongkong, Spain, Provence, Now we have a dedicated and aggressive sales team, and many branches, catering to our main customers. We have been looking for long-term business partnerships, and ensure our suppliers that they will undoubtedly benefit in both short and long run.
A good manufacturers, we have cooperated twice, good quality and good service attitude.








